Finger oximeter with dual-color OLED display,PR.SP02 for babies
Finger oximeter with dual-color OLED display,PR.SP02 for babies
The scope of application
Pulse Oximeter can be detected SPO2 and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) etc.
Fingertip Oximeter Features:
Dependable Oxygen level and Pulse Rate Simple operation ,Small & lightweight design, portable Low power consumption Display SpO2, PR, Pulse Bar Dual color OLED display 2 AAA alkaline batteries Low Battery indication Auto power off Accommodates widest range of finger sizes from pediatric to adult Soft Silicone Padding, Strong Slip Resistant Clip, No Pricking
Technical specification:
Patient rangeAdult, pediatrics
SpO2Measuring range: 35% - 99%Resolution: 1%Accuracy: 70% - 99% : ±2%, 35%~69%: unspecified
PRMeasuring range: 30bpm – 250bpmResolution: 1bpmAccuracy: ±3%
Display Type: Dual-color OLED DisplayParameter: SpO2, SpO2 wave form, PR and Pulse BarMode: 1 display mode
Alarm:Battery-low indicator
Battery: 2 AAA alkaline batteriesNormal operation time is about 20 hours.
Operation:
Temperature: 5°C ~ +40°CHumidity: 15% ~ 90% (non-condensing)Atmospheric pressure: 700hpa ~ 1060hpa
Storage:
Temperature: -20°C ~ +70°CHumidity: 5% ~ 95%Atmospheric pressure: 500hpa ~ 1060hpa
Electromagnetic CompatibilityThe product complies with IEC60601-1-2 for electromagnetic compatibility Class B
Interference Resistance Capacity against Ambient LightDeviation is smaller than ±1% between values of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.